Every water job is an evaporation problem. Water in a subfloor, a wall cavity or a slab has to turn into vapor, the vapor has to move into the room air, and the room air has to give it up to a dehumidifier. Psychrometrics is the set of measurements that tells you whether each step is happening. It is also the language of the drying log, the document that proves to a carrier that the equipment on the invoice was needed and that it worked.
The five quantities and what each tells you
A hygrometer reads temperature and relative humidity. Everything else is derived from those two. A psychrometric chart, a calculator such as the one on this site, or the field app does the conversion.
- Temperature. Warm air can hold more moisture than cool air, and warm materials release moisture faster. On its own it says nothing about how much water the air contains.
- Relative humidity (RH). How close the air is to saturation at its current temperature, as a percentage. It tells you how readily the air will accept more vapor right now, not how much vapor is in it.
- Humidity ratio, in grains per pound (GPP). The weight of water vapor carried by each pound of dry air; 7,000 grains make one pound. It does not change when the air is heated or cooled, which is why it is the number you compare.
- Dew point. The temperature at which the air, holding its current moisture, becomes saturated. Cool a surface below it and water condenses. It is another way of stating absolute moisture, and it warns of condensation on cold windows, ducts and slabs.
- Vapor pressure differential. Vapor moves from higher pressure to lower. A wet material has a high vapor pressure at its surface; dry air has a low one. That gap drives evaporation, and every piece of drying equipment exists to widen it: air movers by clearing saturated air from the surface, heat by raising the pressure at the material, dehumidifiers by lowering it in the room.
Why RH misleads and GPP compares
Relative humidity is a ratio, and the denominator moves with temperature. Air at 60 F and 70 percent RH and air at 80 F and 36 percent RH hold roughly the same water, about 55 grains per pound each. Heat the first room and the RH drops with no water removed. Dehumidify the second and the RH can rise overnight as the room cools, even though the air is drier.
GPP takes temperature out of the comparison. Two readings in grains can be set side by side whatever the thermometer says: room against room, today against yesterday, dehumidifier inlet against outlet, inside against outside. That is why a reviewer looks at the GPP column first, and why its trend is the clearest picture of whether a job is drying.
The four readings of a drying log
ANSI/IICRC S500, the standard for professional water damage restoration (the 2021 edition is current), expects psychrometric readings to be taken and recorded at least daily and names the conditions a complete record covers. Each answers a different question.
- Outside. The air the building exchanges with every time a door opens. If outside grains are lower than inside, ventilation can help; if higher, every opening adds load. It also explains swings the equipment did not cause.
- Unaffected area. A dry room in the same building, away from the loss. It shows what normal looks like for this structure today and is where the dry standard comes from.
- Affected area. The air in the drying chamber, taken away from an air mover's blast and a dehumidifier's discharge. This is the number that must trend down day over day. Each chamber gets its own reading.
- Dehumidifier outlet. The air leaving each unit. Compared with the air going in, it shows whether that unit is removing water. Every unit gets its own reading; one good unit does not excuse a dead one.
| Reading | Temperature | RH | GPP | What it says |
|---|---|---|---|---|
| Outside | 66 F | 72% | roughly 69 | Cooler but damp; opening up would not help much |
| Unaffected area | 72 F | 47% | roughly 55 | Normal for this building today |
| Affected area | 72 F | 65% | roughly 77 | About 22 grains above normal; wet materials are loading the air |
| Dehumidifier outlet | 92 F | 16% | roughly 36 | About 40 grains below its inlet; the unit is pulling |
Reading a dehumidifier
A dehumidifier is judged on the job by one comparison: grains in the air going in against grains in the air coming out. The difference is the grain depression. Inlet air is read at the intake, usually close to the affected-area reading; outlet air at the discharge. The outlet is warmer, so its RH looks low; read the grains.
A healthy unit shows a wide depression on day one that narrows as the room dries, because there is less moisture to take. A depression that is narrow on day one, or that collapses while the affected area is still well above the unaffected area, means the unit is not pulling. The usual reasons are mundane: a clogged filter, an iced coil, an intake sitting in another unit's discharge, a unit running outside its temperature range, or a unit too small for the load the air movers create.
Evaporation, airflow and temperature
Dehumidifiers do not dry materials. They dry air. Materials dry by evaporation, which happens at the surface, where a thin layer of air sits close to saturation. Air movers strip that layer away and replace it with drier room air, which keeps the vapor pressure gap open. Without airflow, the surface air reaches equilibrium with the material and evaporation slows to a crawl.
Temperature works on the other side of the gap. Warmer material has a higher surface vapor pressure, and warmer air carries more moisture away. But heat without enough dehumidification only moves water from the material into the air, and the grains in the room climb until the gap closes again. Airflow lifts moisture off the surface, heat speeds it up, dehumidification takes it out of the room, and the log shows whether the three are balanced.
Drying goals and dry standards
A material is dry when it is back to the moisture content it would have had in that building without the loss. That value is the dry standard, and it is measured, not assumed: read the same material with the same meter in an unaffected part of the same structure, for example the subfloor in a dry bedroom when the loss is in the hallway, and record where it was taken.
The drying goal is the target for the affected material, set against that dry standard before the equipment goes in and written on the log with the date and the meter used. Track each affected material toward it at least daily. The job is done when every monitored material has reached its goal, the affected-area air is back in line with the unaffected area, and the readings that show it are recorded.
A worked drying log over four days
The table follows the affected area from the day-one readings above: a plywood subfloor under a hallway, read with a pin meter. The dry standard from the subfloor in an unaffected bedroom was 11 percent; the goal was set at 12 percent. Grains are rounded calculator values at sea level.
| Day | Temperature | RH | GPP | Subfloor MC | Reading |
|---|---|---|---|---|---|
| 1 | 72 F | 65% | roughly 77 | 24% | Equipment set; air loaded from the wet floor |
| 2 | 76 F | 52% | roughly 70 | 19% | Room warming, grains falling, material releasing water |
| 3 | 78 F | 44% | roughly 63 | 15% | Steady; depression narrowing as expected |
| 4 | 78 F | 38% | roughly 54 | 12% | Goal met; air matches the unaffected area; equipment pulled |
Read two columns at once. Grains fall by seven to nine a day while material moisture falls by three to five points. The two move together, the signature of a job that is drying. RH fell from 65 to 38 percent while the room warmed six degrees, so part of that drop is warming; the grains column is the one to trust.
Recognizing a stall
A stall is a day on which the numbers stop moving: affected-area grains hold or rise and the material reading does not fall. One flat day can be weather or a door left open. Two flat days with equipment running is a problem to diagnose, and the log usually points at one of three causes.
- The air at the material has reached equilibrium. Room grains are close to the grains at the wet surface, so the vapor pressure gap has closed. The room reads only a little above the unaffected area while the material refuses to fall: the air is dry enough but is not being exchanged at the surface. Check airflow across the wet material, look for moisture trapped under a vapor barrier or a floating floor or inside a cavity, and open the assembly if the meter says so.
- Dehumidification is undersized for the evaporation load. The air movers lift more water into the air than the dehumidifiers take out. Grains rise after the equipment goes in and stay well above the unaffected area. Add or upsize dehumidification, or run fewer air movers until the balance holds.
- The space is open to outside air. A window, a garage door, an unsealed return or an HVAC system pulling from outside is feeding damp air into the chamber. The outside reading is at or above the affected area, and the room tracks the weather. Close the chamber, and keep the outside reading in the log so the cause is visible.
What adjusters look for in the log
A carrier reviewer rarely checks the arithmetic. They look for whether the record is complete and whether it tells a consistent story.
- Readings at least once a day from the first day of equipment to the last, with dates and times, and no gaps on weekends.
- All four conditions: outside, unaffected, affected and each dehumidifier outlet.
- A dry standard with its source, a goal set against it, and material readings that reach the goal before the equipment is pulled.
- Equipment counts that fit the loss and that come off the job as areas reach goal rather than all on the last day.
- An explanation for any flat day: what was found, what was changed, and what happened next.
The log is read next to the equipment invoice. A dehumidifier that never shows a depression, or an air mover count that does not change as the materials dry, invites a reduction. Sharing the log as it builds, for example through the adjuster portal in AIFSOP, lets the reviewer watch the trend form rather than receive the numbers after the fact.
Common documentation mistakes
- Recording RH without temperature, or the reverse. One without the other cannot be converted to grains.
- Taking the affected-area reading in front of an air mover or at a dehumidifier discharge, which records the equipment's number rather than the room's.
- Logging one dehumidifier when three are on the job, or one affected area when the loss spans two chambers.
- Skipping the outside reading, which leaves a flat day with no explanation.
- Assuming a dry standard from memory instead of measuring it in this building, or setting the goal after the fact to match the last reading.
- Filling in a missed day later from memory. A gap is a gap; a reconstructed reading is a credibility problem.
None of this needs more than a hygrometer, a moisture meter, a chart or calculator, and the discipline to read the same places at the same times every day. Recording all of them, every day, is what separates a log that gets paid from one that gets questioned.